Answer:
a)step-down" transformer
b) 1440 turns
Explanation:
There are two types of transformers; step up transformers and step down transformers. A step down transformer converts a higher voltage to a lower voltage.
In a stepdown transformer, there are more turns in the primary coil than in the secondary coil, the turns ratio Ns/Np is less than 1 for a stepdown transformer.
If
Number of turns in primary coil Np= 2760
Number of turns in secondary coil Ns= unknown
Voltage in primary coil Vp= 230 V
Voltage in secondary coil Vs= 120 V
Ns/Np= Vs/VP
NsVp= NpVs
Ns= NpVs/VP = 2760 × 120/230
Ns= 1440 turns